HogarProductosSensores ambientalesSensor de lluvia y nieve con calefacción para monitoreo meteorológico.
  • Sensor de lluvia y nieve con superficie de detección calefactada.
  • conductive-grid-rain-snow-sensor-detection-principle.
  • heated-vs-non-heated-rain-snow-sensor-comparison

Sensor de lluvia y nieve con calefacción para monitoreo meteorológico.

Características principales

  • Detección de la presencia de lluvia y nieve: Detects precipitation contact using a conductive sensing surface.

  • Fast response: Less than 1 second response time for timely weather status monitoring.

  • Optional automatic heating: Helps reduce residual moisture and snow accumulation on the sensing surface.

  • Electrodo de rejilla chapado en oro: Provides corrosion resistance for outdoor monitoring applications.

  • IP67 protection: Sealed housing designed for demanding outdoor environments.

  • Salida RS485 Modbus RTU: Enables integration with compatible industrial data acquisition equipment.

  • Múltiples configuraciones de salida: Relay, 4–20mA, voltage, NPN, and combined outputs.

  • Optional wireless communication: LoRa, Bluetooth, WiFi, GPRS, 4G, NB-IoT, and CAT-1 versions are listed.

  • 12–24V DC power supply: Suitable for compatible outdoor monitoring power systems.

  • Recommended 15° installation angle: Helps rainwater drain from the sensing surface.

  • Amplio rango de temperatura de funcionamiento: -30°C to +70°C.

Descripción del Producto

El JW-CQ11(YN10) Rain Snow Sensor is an outdoor precipitation detection device designed to detect the presence of rain or snow in automatic weather stations, road weather monitoring systems, agricultural facilities, and industrial weather alarm applications.

Using a corrosion-resistant gold-plated conductive grid electrode, the sensor provides rapid rain and snow presence detection with a response time of less than 1 second.

Optional automatic heating helps reduce moisture and snow accumulation on the sensing surface in cold environments, supporting more reliable monitoring and recovery between precipitation events.

With RS485 Modbus RTU, relay, analog, NPN, and optional wireless output configurations, the JW-CQ11(YN10) can be integrated into PLCs, RTUs, weather station data loggers, and IoT monitoring platforms.

1. What Is a Rain Snow Sensor?

A rain snow sensor, also called a rain and snow detector or precipitation presence sensor, is used to determine whether precipitation is occurring at a monitoring location.

Unlike a rain gauge, which measures accumulated rainfall or precipitation intensity, a rain and snow presence sensor provides a qualitative indication of precipitation conditions.

The JW-CQ11(YN10) uses a conductive sensing grid to detect water-related changes on its sensing surface and generate a corresponding electrical signal.

Its main function is to support applications that need an indication of precipitation presence for monitoring, alarms, or external automated control.

Typical applications include automatic weather stations, road weather information systems, airport and port monitoring facilities, greenhouse automation, and industrial outdoor safety monitoring.

For complete meteorological monitoring projects, see the JW-IoT Weather Monitoring Station Solution.

2. How Does the Conductive Rain Snow Sensor Work?

The JW-CQ11(YN10) uses a conductive grid electrode combined with electronic detection circuitry.

When rainwater or melted snow contacts the electrode, the electrical characteristics of the sensing surface change.

The detection circuit processes this change and generates a precipitation presence signal.

2.1 Gold-Plated Conductive Grid

The sensing surface uses a gold-plated grid electrode.

Gold plating improves resistance to corrosion and helps protect the sensing surface during outdoor use.

The electrode detects conductive moisture contact rather than measuring precipitation depth or accumulated water volume.

2.2 Precipitation Detection and Signal Processing

When moisture establishes an electrical path across the sensing grid, the circuit can identify the change and produce a corresponding output signal.

The sensor has a published response time of less than 1 second and a stabilization time of less than 1 second.

Actual detection behavior may be affected by precipitation conditions, surface contamination, water conductivity, and the selected configuration.

2.3 Does It Distinguish Rain from Snow?

The published specification identifies rain and snow presence detection but does not establish a separate classification accuracy for rain versus snow.

Therefore, the JW-CQ11(YN10) should primarily be treated as a precipitation presence detector, unless the selected output protocol and supporting documentation explicitly confirm separate rain and snow status codes.

For more detailed weather classification, the monitoring system may need additional temperature, humidity, or specialized precipitation sensors.

3. Optional Heating for Cold Weather Monitoring

Why Is Heating Important?

Cold environments create additional challenges for precipitation sensors.

Snow, frost, and residual water may remain on the sensing surface after precipitation has stopped.

If moisture remains in contact with the conductive electrode, the system may continue indicating wet conditions even after the event has ended.

An optional heating function helps reduce accumulation and supports drying of the sensing surface.

How Heating Supports Sensor Operation

Heating can help:

  • Reduce snow and ice accumulation on the detection surface.
  • Accelerate drying after rain or snow events.
  • Reduce prolonged wet-state signals caused by residual moisture.
  • Improve measurement availability during cold weather.
  • Support unattended precipitation monitoring installations.

The function is especially useful for winter weather stations, road monitoring networks, and remote environmental sensing systems.

Importante: Heating is an optional configuration, not a guaranteed standard feature.

The published product page does not specify heater power consumption, switching temperature, heating control thresholds, or ice-melting capacity. These details should be confirmed for the selected product version.

For solar-powered monitoring stations, heater energy requirements must be considered when sizing the battery and power system.

4. Especificaciones técnicas

Parámetro Especificación
Modelo JW-CQ11(YN10)
Tipo de sensor Rain / Snow Presence Detection Sensor
Principio de detección Conductive Grid Electrode
Electrode Material Gold-Plated Grid
Parámetro de medición Rain and Snow Presence
Tiempo de respuesta Menos de 1 segundo
Tiempo de estabilización Menos de 1 segundo
Fuente de alimentación 12–24 V CC
Función de calefacción Opcional
Temperatura de funcionamiento -30°C to +70°C
Humedad de funcionamiento 10–90% RH
Temperatura de almacenamiento -40°C a +80°C
Humedad de almacenamiento 10–90% RH
Clasificación de protección IP67
Ángulo de instalación recomendado 15° from Horizontal
Salida digital RS485 Modbus RTU
Salida de relé Normally Open
Salida actual 4–20 mA
Salida de voltaje 0–2V / 0–5V / 0–10V
Transistor Output NPN Optional
Salida combinada Multiple Outputs Available
Opciones inalámbricas LoRa, Bluetooth, WiFi, GPRS, 4G, NB-IoT, CAT-1

5. Rain Snow Sensor Output and Communication Options

Different industrial systems require different electrical interfaces. The JW-CQ11(YN10) offers several output configurations for integration into existing monitoring infrastructure.

5.1 RS485 Modbus RTU Rain Snow Sensor

The RS485 Modbus RTU version is suitable for data loggers, PLCs, RTUs, and industrial IoT gateways.

In a typical monitoring system, the controller reads the sensor’s precipitation status through a compatible RS485 interface.

Possible system functions include:

  • Precipitation presence monitoring
  • Status recording
  • Rain or snow event alerts
  • Remote equipment supervision
  • Integration with environmental data
  • Cloud-based monitoring through an external gateway

For successful integration, confirm the Modbus address, serial settings, register definitions, status encoding, and wiring diagram.

5.2 Relay Output for Weather Alarm Systems

The normally open relay output is suitable for compatible alarm and control circuits.

A PLC or weather monitoring controller can read the relay state and execute project-defined actions.

For example, the controller may generate a precipitation warning or temporarily stop a weather-sensitive operation.

Relay contact ratings and permissible switching loads must be confirmed before connecting external equipment.

5.3 Analog and NPN Output

The listed analog output options include 4–20mA and selectable voltage signals.

An optional NPN output is also available.

These interfaces allow the sensor to connect with different types of industrial acquisition equipment.

For analog configurations, engineers should confirm the mapping between the precipitation status and the electrical output value.

5.4 Wireless Integration Options

Optional communication configurations listed for the product include LoRa, Bluetooth, WiFi, GPRS, 4G, NB-IoT, and CAT-1.

Availability and technical configuration may differ between versions.

For remote installations, the communication method should be selected according to network coverage, power availability, reporting requirements, and platform compatibility.

6. Rain Snow Sensor Applications

6.1 Automatic Weather Stations

Automatic weather stations often collect air temperature, relative humidity, atmospheric pressure, wind, rainfall, and other environmental measurements.

A rain snow presence sensor adds a fast precipitation status signal to this monitoring network.

It can help indicate when precipitation begins or when moisture remains on the sensing surface.

For weather stations requiring rainfall quantity, a dedicated rain gauge should be used alongside the rain snow sensor.

Explora el JW-IoT Weather Monitoring Station para el monitoreo meteorológico integrado.

6.2 Road Weather and Highway Monitoring

Road weather monitoring systems require information about changing environmental conditions.

Rain and snow detection can contribute to monitoring precipitation events affecting roads, bridges, expressways, and other transport infrastructure.

The JW-CQ11(YN10) can provide a precipitation presence signal to a roadside monitoring controller.

The controller may combine this information with air temperature, humidity, pavement temperature, visibility, and road surface condition measurements.

For direct pavement classification, such as dry, wet, icy, or snowy road conditions, a dedicated Sensor de estado de la superficie de la carretera is more appropriate.

A rain snow sensor should not be treated as a replacement for road ice detection equipment.

6.3 Airport and Port Weather Monitoring

Airport and port operations can be affected by rain, snow, and changing surface conditions.

Precipitation detection signals may be integrated into local environmental monitoring systems to improve awareness of current weather conditions.

For critical operational decisions, the sensor should be used as part of a broader monitoring system designed according to applicable operational requirements.

6.4 Smart Agriculture and Greenhouse Automation

Agricultural systems may use precipitation presence detection for outdoor irrigation supervision, greenhouse environmental monitoring, or weather-related control functions.

For example, a controller can use a precipitation status input to suspend scheduled outdoor irrigation when rain is detected, subject to the configured control strategy.

In greenhouse projects, the sensor may be installed outside the growing structure as part of a wider environmental monitoring system.

For integrated agriculture applications, see the Sistema de monitorización de invernaderos JW-IoT.

6.5 Industrial Outdoor Equipment Protection

Industrial sites may need to monitor weather conditions affecting exposed equipment.

A precipitation presence sensor can provide a signal for external weather alarms and equipment supervision systems.

Applications may include outdoor handling areas, exposed automation equipment, industrial facilities, and remote infrastructure.

Any shutdown or protective response must be implemented and validated by the external control system.

7. Rain Snow Sensor vs Rain Gauge vs Road Surface Sensor

These instruments provide different measurements and should be selected according to the project objective.

Tipo de sensor Primary Function Typical Output
Rain Snow Sensor Detect precipitation presence Wet/dry or precipitation status
Pluviómetro de cubeta basculante Measure accumulated rainfall Cantidad de lluvia
Pluviómetro óptico Measure rainfall using optical detection Rainfall-related measurement
Sensor de estado de la superficie de la carretera Identify road surface conditions Surface condition classification

When Should You Use a Rain Snow Sensor?

Choose a rain snow detector when the main requirement is to determine whether precipitation is present and provide an input to monitoring or automated control systems.

When Is a Rain Gauge More Suitable?

A rain gauge is appropriate when the project requires rainfall depth, event accumulation, or precipitation intensity.

When Is a Road Surface Sensor Necessary?

A specialized road surface sensor is required when the application needs to distinguish pavement states such as wet, icy, snowy, or dry.

These devices can be combined in a more comprehensive winter weather monitoring network.

8. Integration into an IoT Weather Monitoring System

The JW-CQ11(YN10) can be integrated with compatible monitoring hardware to support centralized precipitation status monitoring.

Una arquitectura típica es:

Rain Snow Sensor → RS485 / Relay Input → PLC or RTU → Communication Gateway → Cloud Monitoring Platform

Step 1: Detect Precipitation

The conductive electrode detects the presence of moisture on the sensing surface.

Step 2: Acquire the Sensor Signal

A compatible PLC, RTU, or data logger reads the digital, analog, or switching signal.

Step 3: Process Weather Status

The control system interprets the acquired data according to the selected sensor configuration.

Project-specific logic may include alarm delays, status confirmation, and event logging.

Step 4: Transmit Monitoring Data

A communication gateway can forward precipitation status information through a suitable communication network.

Step 5: Display and Respond

A monitoring platform can display weather status, store event records, and generate notifications according to the configured rules.

Cloud services, communication hardware, and alarm functions are components of the wider system rather than guaranteed standalone sensor capabilities.

9. Installation Guidelines

Correct installation helps reduce false detections caused by accumulated water, contamination, or inappropriate mounting.

9.1 Maintain the Recommended 15° Angle

Install the sensing surface at approximately 15° from the horizontal plane, as specified in the product instructions.

This helps rainwater drain from the conductive grid and reduces unnecessary moisture accumulation.

9.2 Select an Open Monitoring Position

Choose a location that allows precipitation to reach the sensing surface without major obstruction.

Avoid locations directly beneath roof edges, water discharge pipes, or structures that create misleading water runoff.

9.3 Avoid Environmental Interference

The manufacturer’s installation notes recommend keeping the sensor away from:

  • Chemical corrosion sources
  • Strong external heat sources
  • High-voltage equipment
  • Falling objects
  • Heavy surface contamination

9.4 Protect Power and Signal Wiring

Use appropriate waterproof connectors, cable supports, grounding, and surge protection according to the installation environment.

Confirm the supply voltage and output wiring before energizing the device.

9.5 Check the Heating Configuration

For heated versions, verify the selected heater configuration and total power requirement.

Do not assume that the sensor’s general operating voltage specification alone establishes heater power consumption.

10. Maintenance Recommendations

Routine inspection is important for conductive precipitation sensors because dirt, corrosion, and moisture residue may affect electrical detection.

El mantenimiento recomendado incluye:

  • Inspecting the conductive grid for dirt and deposits.
  • Cleaning the surface using manufacturer-approved methods.
  • Checking that the sensing surface remains correctly inclined.
  • Inspecting cable connections and seals.
  • Checking the sensor status under suitable test conditions.
  • Verifying heater operation when the heating option is installed.

Avoid abrasive cleaning methods that could damage the gold-plated sensing grid.

For remote monitoring stations, maintenance intervals should be selected according to local environmental conditions and operational requirements.

11. How to Select the Right Rain Snow Detector

Before purchasing a rain snow sensor, system integrators should confirm the following project requirements.

Detection objective: Is the system intended to identify precipitation presence, rainfall amount, snow depth, or road icing?

Interfaz de salida: Does the controller require RS485 Modbus RTU, relay, 4–20mA, voltage, or NPN output?

Heating requirement: Will the sensor operate in conditions where frost, snowfall, or residual moisture may affect detection?

Fuente de alimentación: Is 12–24V DC available, and is sufficient power provided for the selected heating option?

Communication architecture: Will the sensor be connected directly to a PLC or through an RTU and remote gateway?

Entorno de instalación: What are the minimum temperature, contamination exposure, mounting constraints, and maintenance requirements?

Configuration: Are wired, combined, or wireless output options necessary?

For complete environmental monitoring projects, the JW-IoT Ambient Sensor Product Category provides other sensing options that can complement precipitation detection.

12. Request a Rain Snow Sensor for Your Project

El JW-CQ11(YN10) Rain Snow Sensor with Optional Heating is a precipitation presence detection solution for automatic weather stations, smart transportation, agricultural monitoring, and industrial environmental automation.

With fast response, an IP67 housing, and multiple signal output options, the sensor can be configured for integration into different weather monitoring architectures.

JW-IoT can help customers review sensor selection, electrical interface requirements, and system integration needs.

Looking for an RS485 rain snow sensor or a heated precipitation detector for your next project?

Contact JW-IoT for Technical Support and Quotation

Preguntas frecuentes

  • Q

    1. What does the JW-CQ11(YN10) rain snow sensor measure?

    A

    It detects the presence of rain or snow using a conductive grid electrode. It is primarily intended for qualitative precipitation status detection.

  • Q

    2. Does this rain snow detector measure rainfall in millimeters?

    A

    No rainfall accumulation or intensity measurement is specified. A dedicated rain gauge is required for quantitative rainfall measurement.

  • Q

    3. Is the heating function included as standard?

    A

    No. Heating is listed as an optional function and should be specified when ordering.

  • Q

    4. What is the response time?

    A

    The published response time and stabilization time are both less than 1 second.

  • Q

    5. ¿El sensor es compatible con RS485 Modbus RTU?

    A

    Yes. RS485 Modbus RTU is one of the available output configurations.

  • Q

    6. Can it connect to a PLC?

    A

    Yes. The sensor can be integrated with a compatible PLC using the selected RS485, relay, analog, or NPN output interface.

  • Q

    7. Is the sensor suitable for outdoor installation?

    A

    The product has a published IP67 protection rating and an operating temperature range of -30°C to +70°C.

  • Q

    8. What is the recommended installation angle?

    A

    The sensing surface should be installed at approximately 15° from horizontal.

  • Q

    9. Can the sensor connect to a cloud platform?

    A

    Yes, through an appropriate controller, data logger, communication gateway, or supported wireless configuration.

  • Q

    10. Can heating prevent false alarms?

    A

    Heating can help reduce moisture and snow accumulation that may prolong wet-state detection. However, it does not guarantee the elimination of all false alarms.

  • Q

    11. What information is required when requesting a quotation?

    A

    Please specify the required quantity, output interface, heating requirement, power supply arrangement, installation environment, communication preferences, and destination country.

WhatsApp

¡Dejar un mensaje!

¡Dejar un mensaje!